Follow
Hai Zheng
Hai Zheng
University of Pittsburgh
No verified email
Title
Cited by
Cited by
Year
High‐resolution sodium imaging of human brain at 7 T
Y Qian, T Zhao, H Zheng, J Weimer, FE Boada
Magnetic Resonance in Medicine, 2011
472011
Sodium imaging of human brain at 7 T with 15‐channel array coil
Y Qian, T Zhao, GC Wiggins, LL Wald, H Zheng, J Weimer, FE Boada
Magnetic Resonance in Medicine, 2012
462012
Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding
Y Zhao, T Zhao, SB Raval, N Krishnamurthy, H Zheng, CT Harris, ...
Magnetic resonance in medicine 74 (5), 1461-1469, 2015
172015
Improved large tip angle parallel transmission pulse design through a perturbation analysis of the Bloch Equation
H Zheng, T Zhao, Y Qian, TS Ibrahim, FE Boada
Magnetic Resonance in Medicine 66 (3), 687-696, 2011
172011
Parallel transmission RF pulse design for eddy current correction at ultra high field
H Zheng, T Zhao, Y Qian, T Ibrahim, F Boada
Journal of Magnetic Resonance, 2012
122012
Multi-slice parallel transmission three-dimensional tailored RF (PTX 3DTRF) pulse design for signal recovery in ultra high field functional MRI
H Zheng, T Zhao, Y Qian, C Schirda, TS Ibrahim, FE Boada
Journal of Magnetic Resonance 228, 37-44, 2013
102013
A fast B1 mapping method for transmit/receive coils for parallel transmit (PTX) applications
T Zhao, H Zheng, A DeFranco, T Ibrahim, Y Qian, F Boada
International Society of Magnetic Resonance in Medicine, 2011
62011
Decoupled Sets of Coupled Coils: An 8-20 Channel Subject-Insensitive Array for 7T Applications
TS Ibrahim, T Zhao, E Jefferies, H Zheng, FE Boada
Proc Intl Soc Mag Reson Med (Stockholm, Sweden), 3821, 2010
32010
Maximizing RF efficiency and minimizing eddy current artifacts using RF and eddy current simulations
Y Zhao, D Stough, H Zheng, T Zhao, CT Harris, WB Handler, BA Chronik, ...
International Society of Magnetic Resonance in Medicine Melbourne, 536, 2012
22012
Practical consideration for the design of parallel transmission pulses at ultra high field
T Zhao, H Zheng, YK Hue, TS Ibrahim, Y Qian, FE Boada
Proceedings of the 19th Scientific Meeting, International Society for …, 2011
22011
Fast and Accurate Large-Tip-Angle RF Pulse Design for Parallel Excitation Using a Perturbation Analysis of the Bloch Equation
H Zheng, TJ Zhao, T Ibrahim, FE Boada
Proceedings of the 18th Annual Meeting of ISMRM, 2010
22010
Eddy-Current-Compensated RF Pulse Design for Parallel Excitation
H Zheng, T Zhao, T Ibrahim, FE Boada
JMR 90, 264-278, 1990
2*1990
Using the Binomial RF Pulses for Selective Excitation of the Ultra-shot T2 Component
T Zhao, H Zheng, Y Qian, TS Ibrahim, F Boada
Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012
12012
Improved response to face recognition in UHF fMRI through parallel transmission RF pulse design
H Zheng, T Zhao, K Edelman, Y Qian, TS Ibrahim, H Aizenstein, FE Boada
F1000 Research, 2012
2012
Effect of Trajectory Design on Susceptibility Compensation of Whole Brain Parallel Transmission for UHF fMRI
FB Hai Zheng, Tiejun Zhao, Yongxian Qian, Tamer Ibrahim
Proceedings 20th Ann. Meet. Intl. Soc. Mag. Reson. Med., Melbourne, Australia, 2012
2012
Robustness and Reproducibility of PTX 3DTRF Pulse Design for Ultra High Field fMRI
FB Hai Zheng, Lei Sheu, Tiejun Zhao, Yongxian Qian, Tamer Ibrahim, Howard ...
Proceedings 20th Ann. Meet. Intl. Soc. Mag. Reson. Med., Melbourne, Australia, 2012
2012
RF pulse design for parallel transmission in ultra high field Magnetic Resonance Imaging
H Zheng
University of Pittsburgh, 2012
2012
High Resolution Sodium MRI on Human Brain at 7T
Y Qian, T Zhao, J Weimer, H Zheng, FE Boada
Proc. Intl. Soc. Mag. Reson. Med 19, 3509, 2011
2011
Through-plane Signal loss recovery and B1 inhomogeneity reduction in vivo at 7T using parallel transmission
H Zheng, T Zhao, Y Qian, T Ibrahim, F Boada
Proc. Intl. Soc. Mag. Reson. Med 19, 213, 2011
2011
Characterization and correction of eddy currents for ultra high field parallel transmission with RF pulse design
H Zheng, T Zhao, Y Qian, T Ibrahim, F Boada
Proc. Intl. Soc. Mag. Reson. Med 19, 4440, 2011
2011
The system can't perform the operation now. Try again later.
Articles 1–20