A novel 9.4 Tesla FTICR mass spectrometer with improved sensitivity, mass resolution, and mass range NK Kaiser, JP Quinn, GT Blakney, CL Hendrickson, AG Marshall Journal of the American Society for Mass Spectrometry 22 (8), 1343-1351, 2011 | 258 | 2011 |
21 Tesla Fourier transform ion cyclotron resonance mass spectrometer: a national resource for ultrahigh resolution mass analysis CL Hendrickson, JP Quinn, NK Kaiser, DF Smith, GT Blakney, T Chen, ... Journal of the American Society for Mass Spectrometry 26 (9), 1626-1632, 2015 | 249 | 2015 |
Parts-per-billion Fourier transform ion cyclotron resonance mass measurement accuracy with a “walking” calibration equation JJ Savory, NK Kaiser, AM McKenna, F Xian, GT Blakney, RP Rodgers, ... Analytical chemistry 83 (5), 1732-1736, 2011 | 236 | 2011 |
Closed network growth of fullerenes PW Dunk, NK Kaiser, CL Hendrickson, JP Quinn, CP Ewels, Y Nakanishi, ... Nature communications 3 (1), 855, 2012 | 206 | 2012 |
The Smallest Stable Fullerene, M@C28 (M = Ti, Zr, U): Stabilization and Growth from Carbon Vapor PW Dunk, NK Kaiser, M Mulet-Gas, A Rodríguez-Fortea, JM Poblet, ... Journal of the American Chemical Society 134 (22), 9380-9389, 2012 | 201 | 2012 |
Expansion of the analytical window for oil spill characterization by ultrahigh resolution mass spectrometry: beyond gas chromatography AM McKenna, RK Nelson, CM Reddy, JJ Savory, NK Kaiser, ... Environmental science & technology 47 (13), 7530-7539, 2013 | 163 | 2013 |
Electrically compensated Fourier transform ion cyclotron resonance cell for complex mixture mass analysis NK Kaiser, JJ Savory, AM McKenna, JP Quinn, CL Hendrickson, ... Analytical chemistry 83 (17), 6907-6910, 2011 | 119 | 2011 |
Unprecedented ultrahigh resolution FT-ICR mass spectrometry and parts-per-billion mass accuracy enable direct characterization of nickel and vanadyl porphyrins in petroleum … AM McKenna, JT Williams, JC Putman, C Aeppli, CM Reddy, ... Energy & fuels 28 (4), 2454-2464, 2014 | 111 | 2014 |
Identification and characterization of human proteoforms by top-down LC-21 tesla FT-ICR mass spectrometry LC Anderson, CJ DeHart, NK Kaiser, RT Fellers, DF Smith, JB Greer, ... Journal of proteome research 16 (2), 1087-1096, 2017 | 97 | 2017 |
Bottom-up formation of endohedral mono-metallofullerenes is directed by charge transfer PW Dunk, M Mulet-Gas, Y Nakanishi, NK Kaiser, A Rodríguez-Fortea, ... Nature Communications 5 (1), 5844, 2014 | 82 | 2014 |
Unit mass baseline resolution for an intact 148 kDa therapeutic monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry SG Valeja, NK Kaiser, F Xian, CL Hendrickson, JC Rouse, AG Marshall Analytical chemistry 83 (22), 8391-8395, 2011 | 80 | 2011 |
Metallofullerene and fullerene formation from condensing carbon gas under conditions of stellar outflows and implication to stardust PW Dunk, JJ Adjizian, NK Kaiser, JP Quinn, GT Blakney, CP Ewels, ... Proceedings of the National Academy of Sciences 110 (45), 18081-18086, 2013 | 73 | 2013 |
A photocleavable and mass spectrometry identifiable cross-linker for protein interaction studies L Yang, X Tang, CR Weisbrod, GR Munske, JK Eng, PD von Haller, ... Analytical chemistry 82 (9), 3556-3566, 2010 | 71 | 2010 |
Incorporation of a flared inlet capillary tube on a Fourier transform ion cyclotron resonance mass spectrometer S Wu, K Zhang, NK Kaiser, JE Bruce, DC Prior, GA Anderson Journal of the American Society for Mass Spectrometry 17, 772-779, 2006 | 67 | 2006 |
Mass resolution and mass accuracy: how much is enough? AG Marshall, GT Blakney, T Chen, NK Kaiser, AM McKenna, RP Rodgers, ... Mass spectrometry 2 (Special_Issue), S0009-S0009, 2013 | 57 | 2013 |
Controlled Ion Ejection from an External Trap for Extended m/z Range in FT-ICR Mass Spectrometry NK Kaiser, JJ Savory, CL Hendrickson Journal of The American Society for Mass Spectrometry 25 (6), 943-949, 2014 | 52 | 2014 |
Tailored ion radius distribution for increased dynamic range in FT-ICR mass analysis of complex mixtures NK Kaiser, AM McKenna, JJ Savory, CL Hendrickson, AG Marshall Analytical chemistry 85 (1), 265-272, 2013 | 49 | 2013 |
Front-end electron transfer dissociation coupled to a 21 Tesla FT-ICR mass spectrometer for intact protein sequence analysis CR Weisbrod, NK Kaiser, JEP Syka, L Early, C Mullen, JJ Dunyach, ... Journal of The American Society for Mass Spectrometry 28 (9), 1787-1795, 2017 | 47 | 2017 |
Formation of Heterofullerenes by Direct Exposure of C60 to Boron Vapor. PW Dunk, A RodríguezFortea, NK Kaiser, H Shinohara, JM Poblet, ... Angewandte Chemie International Edition 52 (1), 2013 | 42 | 2013 |
Note: Optimized circuit for excitation and detection with one pair of electrodes for improved Fourier transform ion cyclotron resonance mass spectrometry T Chen, SC Beu, NK Kaiser, CL Hendrickson Review of Scientific Instruments 85 (6), 2014 | 32 | 2014 |