Follow
Casey Pirnstill
Casey Pirnstill
Air Force Research Labs
Verified email at us.af.mil
Title
Cited by
Cited by
Year
Malaria Diagnosis Using a Mobile Phone Polarized Microscope
C Pirnstill, G Cote
Scientific Reports 5, 13368, 2015
1982015
In Vivo Glucose Monitoring Using Dual-Wavelength Polarimetry to Overcome Corneal Birefringence in the Presence of Motion
CW Pirnstill, BH Malik, VC Gresham, GL Coté
Diabetes Technology & Therapeutics 14 (9), 819-827, 2012
572012
Dual-wavelength polarimetric glucose sensing in the presence of birefringence and motion artifact using anterior chamber of the eye phantoms
BH Malik, CW Pirnstill, GL Coté
Journal of Biomedical Optics 18 (1), 017007-017007, 2013
342013
Dual-modulation, dual-wavelength, optical polarimetry system for glucose monitoring
ZF Yu, CW Pirnstill, GL Coté
Journal of Biomedical Optics 21 (8), 087001-087001, 2016
152016
Polarimetric glucose sensing in vitro: a high frequency approach
CW Pirnstill, D Grunden, GL Coté
Optical Diagnostics and Sensing XIII: Toward Point-of-Care Diagnostics 8591 …, 2013
72013
Polarimetric glucose sensing in an artificial eye anterior chamber
BH Malik, CW Pirnstill, GL Coté
Optical Diagnostics and Sensing XII: Toward Point-of-Care Diagnostics; and …, 2012
72012
Malaria diagnosis using a mobile phone polarized microscope. Sci Rep 5: 13368
CW Pirnstill, GL Coté
52015
High-speed dual-wavelength optical polarimetry for glucose sensing
DT Grunden, CW Pirnstill, GL and Coté
SPIE BiOS, 8951-39, 2014
52014
Design and Characterization of a Ferromagnetic, Air Gapped Magneto-Optic Faraday Rotator
CW Pirnstill, BH Malik, E Thomas III, GL Coté
Optics Letters 30 (8), 1298-1300, 2013
42013
Modeling the optical coupling across the anterior chamber of the eye towards polarimetric glucose sensing
CW Pirnstill, GL and Coté
SPIE BiOS, 8951-6, 2014
32014
Polarized Light Applications towards Biomedical Diagnosis and Monitoring
CW Pirnstill
22015
Human Digital Twin and Modeling Guidebook
C Pirnstill
12022
ATD biodynamics during lateral impact for USAF neck injury criteria
C Perry, J Buhrman, C Pirnstill, J McIntire
Safety 5 (4), 71, 2019
12019
A closed-loop dual-modulation multi-spectral polarimeter for glucose monitoring
Z fang Yu, CW Pirnstill, GL Coté
Optical Diagnostics and Sensing XVI: Toward Point-of-Care Diagnostics 9715 …, 2016
12016
Glucose Monitoring
CW Pirnstill, B Cummins, GL Cote, RJ McNichols
Biomedical Photonics Handbook: Biomedical Diagnostics 2, 47-68, 2014
12014
Eye coupling mechanism for noninvasive glucose measurements with polarized light
G Cote, J Hanks, C Pirnstill
US Patent 10,987,035, 2021
2021
Dual amplitude modulation and polarization frequency modulation as well as compensation for noninvasive glucose monitoring
GL Cote, DT Grunden, BH Malik, C Pirnstill, E Thomas III
US Patent 10,702,197, 2020
2020
Aircrew Restraint Biodynamics (ARB) During Vertical Deceleration
B Steinhauer, J Buhrman, C Perry, C Pirnstill, EV Patrick, ...
2019
Establishment of Maximum Voluntary Compressive Neck Tolerance Levels
M Cote, J Buhrman, N Bridges, C Pirnstill, C Burneka, J Plaga, G Roush
AIR FORCE RESEARCH LAB WRIGHT-PATTERSON AFB OH HUMAN PERFORMANCE WING (711TH …, 2011
2011
The system can't perform the operation now. Try again later.
Articles 1–19