Follow
Sarah G. Cuddy-Walsh
Sarah G. Cuddy-Walsh
Verified email at hc-sc.gc.ca - Homepage
Title
Cited by
Cited by
Year
Detectors with dual-ended readout by silicon photomultipliers for high resolution positron emission mammography applications
F Taghibakhsh, S Cuddy, T Rvachov, D Green, A Reznik, JA Rowlands
2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), 2821-2826, 2009
122009
Effect of scintillator crystal geometry and surface finishing on depth of interaction resolution in PET detectors: Monte Carlo simulation and experimental results using silicon …
S Cuddy, A Reznik, JA Rowlands, F Taghibakhsh
SPIE Medical Imaging 7622, 76221O, 2010
92010
Patient‐specific estimation of spatially variant image noise for a pinhole cardiac SPECT camera
SG Cuddy‐Walsh, RG Wells
Medical physics 45 (5), 2033-2047, 2018
72018
Multicenter evaluation of the feasibility of clinical implementation of SPECT myocardial blood flow measurement: intersite variability and imaging time
RG Wells, FM Bengel, L Camoni, E Cerudelli, SG Cuddy-Walsh, ...
Circulation: Cardiovascular Imaging 16 (10), e015009, 2023
42023
Patient-specific SPECT imaging protocols to standardize image noise
SG Cuddy-Walsh, DC Clackdoyle, JM Renaud, RG Wells
Journal of Nuclear Cardiology 28 (1), 225-233, 2021
42021
Position-dependent noise in multi-pinhole SPECT
S Cuddy-Walsh, RG Wells
Society of Nuclear Medicine and Molecular Imaging Conference, Journal of …, 2014
42014
Novel methods of resolving energy and 3D positions of interactions in monolithic scintillator plates
F Taghibakhsh, SG Cuddy, JA Rowlands
IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2549-2552, 2010
42010
Improved precision of SPECT myocardial blood flow using a net tracer retention model
SG Cuddy‐Walsh, RA deKemp, TD Ruddy, RG Wells
Medical Physics 50 (4), 2009-2021, 2023
22023
Noise heterogeneity in attenuation-corrected cardiac SPECT images increases perfusion value uncertainty near the base of the heart
SG Cuddy-Walsh, RG Wells
Journal of Nuclear Cardiology 28 (4), 1284-1293, 2021
12021
Base-to-apex noise gradient with dedicated cardiac and standard SPECT camera designs
S Cuddy-Walsh, RG Wells
Society of Nuclear Medicine and Molecular Imaging Conference, Journal of …, 2018
12018
Directional resolution of limited-angle multi-pinhole SPECT cameras
SG Cuddy-Walsh, R Clackdoyle, RG Wells
2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2014
12014
Multi-Center Evaluation of Inter-Site Variability in SPECT Myocardial Blood Flow Measurement
RG Wells, FM Bengel, L Camoni, E Cerudelli, SG Cuddy-Walsh, L Han, ...
Circulation 144 (Suppl_1), A12183-A12183, 2021
2021
Impact of Pinhole Collimation on SPECT Image Quality Metrics, and Methods for Patient-Specific Assessment of Noise and Standardization of Imaging Protocols
SG Cuddy-Walsh
Carleton University, 2019
2019
Evaluating patient-specific z-score images for lesion detection in low count studies
SG Cuddy-Walsh, S Massalha, BF Marvin, C Carey, TD Ruddy, RG Wells
2018 IEEE Nuclear Science Symposium and Medical Imaging Conference …, 2018
2018
Is it noise or abnormality? A method for estimating local noise in a CZT SPECT camera
SG Cuddy-Walsh, RG Wells
Canadian Organization of Medical Physicists Annual Scientific Meeting …, 2017
2017
Weight-based dosing method for consistent image noise levels in dedicated cardiac SPECT
S Cuddy-Walsh, RG Wells
Society of Nuclear Medicine and Molecular Imaging Conference, Journal of …, 2017
2017
Position‐sensitive noise characteristics in multi‐pinhole cardiac SPECT imaging
SG Cuddy‐Walsh, RG Wells
Canadian Organization of Medical Physicists Annual Scientific Meeting …, 2014
2014
High resolution detectors for PET mammography
SG Cuddy, JA Rowlands
Canadian Organization of Medical Physicists Annual Scientific Meeting …, 2012
2012
TU‐G‐211‐02: Design and Evaluation of Dual‐Ended Detectors for PET Mammography
S Cuddy, F Taghibakhsh, J Rowlands
Medical Physics 38 (6Part30), 3786-3786, 2011
2011
Design and Evaluation of Dual-Ended Detectors for PET Mammography
SG Cuddy
University of Toronto, 2011
2011
The system can't perform the operation now. Try again later.
Articles 1–20