The European Joint Research Project UHDpulse–Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates A Schüller, S Heinrich, C Fouillade, A Subiel, L De Marzi, F Romano, ... Physica Medica 80, 134-150, 2020 | 102 | 2020 |
Characterization of the PTB ultra-high pulse dose rate reference electron beam A Bourgouin, A Knyziak, M Marinelli, R Kranzer, A Schüller, RP Kapsch Physics in Medicine & Biology 67 (8), 085013, 2022 | 15 | 2022 |
Measurement methods of ionization current and electric charges in radiation dosimetry AB Knyziak, W Rzodkiewicz Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2016 | 8 | 2016 |
Development and characterization of air kerma cavity standard MM Szymko, L Michalik, AB Knyziak, AW Wójtowicz Measurement 136, 647-657, 2019 | 4 | 2019 |
New X-ray testing methods of aerosol products for industrial radiography AB Knyziak, W Rzodkiewicz, E Kaczorowska, M Derlacinski Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2017 | 4 | 2017 |
Porównanie metod pomiarów małych prądów jonizacyjnych AB Knyziak Przegląd Elektrotechniczny 85 (10), 177-181, 2009 | 4 | 2009 |
Key comparison BIPM. RI (I)-K2 of the air-kerma standards of the GUM, Poland and the BIPM in low-energy x-rays DT Burns, P Roger, AB Knyziak Metrologia 49 (1A), 06002-06002, 2012 | 3 | 2012 |
Metody pomiarów małych prądów jonizacyjnych rzędu 10-15 A AB Knyziak Przegląd Elektrotechniczny 85 (2), 56-58, 2009 | 3 | 2009 |
Graphite ionization chamber as an ionometric standard of absorbed dose to water for Co-60 gamma radiation MM Szymko, AB Knyziak, M Derlaciński Measurement 194, 110928, 2022 | 2 | 2022 |
Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the GUM, Poland and the BIPM in 60Co gamma radiation C Kessler, D Burns, A Knyziak, M Szymko, M Derlaciński Metrologia 58 (1A), 06011, 2021 | 2 | 2021 |
Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the GUM, Poland and the BIPM in 60Co gamma radiation C Kessler, D Burns, A Knyziak, M Szymko, M Derlaciński Metrologia 58 (1A), 06014, 2021 | 2 | 2021 |
Badanie wyrobów aerozolowych metodą promieniowania rentgenowskiego A Czechowski, AB Knyziak Metrologia i Probiernictwo: biuletyn Głównego Urzędu Miar, 36-39, 2015 | 2 | 2015 |
Automation of the measurement system for calibration in the field of gamma radiation AB Knyziak Przeglad Elektrotechniczny 87 (4), 253-259, 2011 | 2 | 2011 |
Wykorzystanie elektrometru Keithley 6517A w układzie kompensacji Townsend'a AB Knyziak Pomiary Automatyka Kontrola 60 (3), 164--166, 2014 | | 2014 |
Key comparison BIPM. RI (I)-K3 of the air-kerma standards of the GUM, Poland and the BIPM in medium-energy x-rays DT Burns, C Kessler, AB Knyziak Metrologia 50 (1A), 06003-06003, 2013 | | 2013 |
Automation of the measurement system for calibration in the field of x-rays AB Knyziak PRZEGLAD ELEKTROTECHNICZNY 86 (5), 30-37, 2010 | | 2010 |