Follow
Xinjie Cao
Xinjie Cao
United Imaging Healthcare America
Verified email at united-imaging.com
Title
Cited by
Cited by
Year
High-resolution depth-encoding PET detector module with prismatoid light-guide array
A LaBella, X Cao, E Petersen, R Lubinsky, A Biegon, W Zhao, AH Goldan
Journal of Nuclear Medicine 61 (10), 1528-1533, 2020
442020
Sub‐2 mm depth of interaction localization in PET detectors with prismatoid light guide arrays and single‐ended readout using convolutional neural networks
A LaBella, X Cao, X Zeng, W Zhao, AH Goldan
Medical Physics 48 (3), 1019-1025, 2021
222021
A conformal TOF–DOI Prism‐PET prototype scanner for high‐resolution quantitative neuroimaging
X Zeng, Z Wang, W Tan, E Petersen, X Cao, A LaBella, A Boccia, ...
Medical physics 50 (6), 3401-3417, 2023
202023
Depth of interaction and coincidence time resolution characterization of ultrahigh resolution time-of-flight prism-PET modules
X Cao, A Labella, X Zeng, W Zhao, AH Goldan
IEEE Transactions on Radiation and Plasma Medical Sciences 6 (5), 529-536, 2021
172021
High‐resolution and high‐sensitivity PET for quantitative molecular imaging of the monoaminergic nuclei: A GATE simulation study
Z Wang, X Cao, A LaBella, X Zeng, A Biegon, D Franceschi, E Petersen, ...
Medical Physics 49 (7), 4430-4444, 2022
112022
36-to-1 multiplexing with Prism-PET for high resolution TOF-DOI PET
A LaBella, E Petersen, X Cao, X Zeng, W Zhao, A Goldan
Journal of Nuclear Medicine 62 (supplement 1), 38-38, 2021
82021
A high resolution and high sensitivity Prism-PET brain scanner with non-cylindrical decagon geometry
Z Wang, X Cao, X Zeng, A LaBella, E Petersen, N Clayton, A Biegon, ...
Journal of Nuclear Medicine 62 (supplement 1), 1136-1136, 2021
42021
Wearable electromagnetic motion tracking with submillimeter accuracy: an experimental study using high-resolution Prism-PET brain scanner
W Tan, Z Wang, X Zeng, X Cao, W Zhao, A Goldan
Journal of Nuclear Medicine 63 (supplement 2), 3320-3320, 2022
32022
Interleaved signal multiplexing readout in depth encoding prism‐PET detectors
Y Li, A LaBella, X Zeng, Z Wang, E Petersen, X Cao, W Zhao, AH Goldan
Medical Physics 50 (7), 4234-4243, 2023
22023
Compton scatter decomposition and recovery in a Prism-PET module
E Petersen, A LaBella, A Howansky, X Cao, W Zhao, A Goldan
Journal of Nuclear Medicine 61 (supplement 1), 1510-1510, 2020
22020
High resolution TOF-DOI prism-PET brain scanner: experimental results from the first prototype scanner
X Zeng, Z Wang, W Tan, X Cao, A Boccia, D Franceschi, A Biegon, ...
Journal of Nuclear Medicine 63 (supplement 2), 2516-2516, 2022
12022
Performance simulation of high resolution and high sensitivity prism-pet brain scanner
E Petersen, P Neilson, A LaBella, A Howansky, X Cao, Z Wang, C Woody, ...
Journal of Nuclear Medicine 61 (supplement 1), 1502-1502, 2020
12020
Arc-PET: A High Sensitivity and High Resolution Conformal Whole-body PET Scanner Based on Prism-PET Detector Modules
Z Wang, X Zeng, W Tan, E Petersen, X Cao, W Zhao, A Goldan
Journal of Nuclear Medicine 64 (supplement 1), P789-P789, 2023
2023
Tapered Scintillator modules and methods of using the same
A LaBella, G Amirhossein, C Xinjie, Z Wei
WO Patent WO 2022/051506 A1, 2022
2022
Prism-PET, Towards High Resolution and High Sensitivity Brain-Dedicated and Whole-Body Next Generation PET Scanner
X Cao
State University of New York at Stony Brook, 2022
2022
Depth-Encoding Based on Optical Photon Time-of-Flight in Prism-PET with Tapered Scintillator Crystals
A LaBella, X Cao, X Zeng, W Zhao, A Goldan
Journal of Nuclear Medicine 62 (supplement 1), 1138-1138, 2021
2021
Flood Histogram Quality Metric for Light Sharing Depth-Encoding PET Modules
A LaBella, X Cao, W Zhao, AH Goldan
2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2020
2020
Flood Histogram Quality of Prism-PET
A LaBella, X Cao, W Zhao, A Goldan
Journal of Nuclear Medicine 61 (supplement 1), 1504-1504, 2020
2020
Depth-of-Interaction and Coincidence Time Resolution Characterization of Ultrahigh Resolution Prism-PET Modules
X Cao, A LaBella, W Zhao, A Goldan
Journal of Nuclear Medicine 61 (supplement 1), 393-393, 2020
2020
The system can't perform the operation now. Try again later.
Articles 1–19