A novel formulation for blood trauma prediction by a modified power-law mathematical model M Grigioni, U Morbiducci, G D’Avenio, GD Benedetto, CD Gaudio Biomechanics and Modeling in Mechanobiology 4, 249-260, 2005 | 177 | 2005 |
The power‐law mathematical model for blood damage prediction: analytical developments and physical inconsistencies M Grigioni, C Daniele, U Morbiducci, G D’Avenio, G Di Benedetto, ... Artificial organs 28 (5), 467-475, 2004 | 172 | 2004 |
A discussion on the threshold limit for hemolysis related to Reynolds shear stress M Grigioni, C Daniele, G D'avenio, V Barbaro Journal of biomechanics 32 (10), 1107-1112, 1999 | 119 | 1999 |
A mathematical description of blood spiral flow in vessels: application to a numerical study of flow in arterial bending M Grigioni, C Daniele, U Morbiducci, C Del Gaudio, G D’Avenio, ... Journal of Biomechanics 38 (7), 1375-1386, 2005 | 110 | 2005 |
The influence of the leaflets’ curvature on the flow field in two bileaflet prosthetic heart valves M Grigioni, C Daniele, G D’Avenio, V Barbaro Journal of Biomechanics 34 (5), 613-621, 2001 | 78 | 2001 |
Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow M Grigioni, C Daniele, U Morbiducci, G D’Avenio, G Di Benedetto, ... Journal of Biomechanics 35 (12), 1599-1612, 2002 | 73 | 2002 |
The beneficial vortex and best spatial arrangement in total extracardiac cavopulmonary connection A Amodeo, M Grigioni, G Oppido, C Daniele, G D'Avenio, G Pedrizzetti, ... The Journal of thoracic and cardiovascular surgery 124 (3), 471-478, 2002 | 54 | 2002 |
Three-dimensional numeric simulation of flow through an aortic bileaflet valve in a realistic model of aortic root M Grigioni, C Daniele, C Del Gaudio, U Morbiducci, A Balducci, ... ASAIO journal 51 (3), 176-183, 2005 | 50 | 2005 |
Investigation of the flow field downstream of an artificial heart valve by means of PIV and PTV A Balducci, M Grigioni, G Querzoli, GP Romano, C Daniele, G D’Avenio, ... Experiments in fluids 36, 204-213, 2004 | 45 | 2004 |
Virtual microscopy and digital cytology: state of the art D Giansanti, M Grigioni, G D'Avenio, S Morelli, G Maccioni, A Bondi, ... Annali dell'Istituto superiore di sanità 46, 115-122, 2010 | 44 | 2010 |
Particle image velocimetry analysis of the flow field in the total cavopulmonary connection M Grigioni, A Amodeo, C Daniele, G D'avenio, R Formigari, RM Di Donato Artificial organs 24 (12), 946-952, 2000 | 38 | 2000 |
19 mm sized bileaflet valve prostheses’ flow field investigated by bidimensional laser doppler anemometry (part I: velocity profiles) V Barbaro, M Grigioni, C Daniele, G D'avenio, G Boccanera The International Journal of Artificial Organs 20 (11), 622-628, 1997 | 32 | 1997 |
Prosthetic heart valves’ mechanical loading of red blood cells in patients with hereditary membrane defects M Grigioni, P Caprari, A Tarzia, G D’Avenio Journal of biomechanics 38 (8), 1557-1565, 2005 | 31 | 2005 |
Innovative technologies for the assessment of cardiovascular medical devices: state-of-the-art techniques for artificial heart valve testing M Grigioni, C Daniele, G D'Avenio, U Morbiducci, C Del Gaudio, M Abbate, ... Expert review of medical devices 1 (1), 81-93, 2004 | 29 | 2004 |
Evaluation of the surface-averaged load exerted on a blood element by the Reynolds shear stress field provided by artificial cardiovascular devices M Grigioni, C Daniele, G D’Avenio, V Barbaro Journal of biomechanics 35 (12), 1613-1622, 2002 | 29 | 2002 |
Mechanically assisted total cavopulmonary connection with an axial flow pump: computational and in vivo study F Gandolfo, G Brancaccio, S Donatiello, S Filippelli, G Perri, E Iannace, ... Artificial Organs 40 (1), 43-49, 2016 | 27 | 2016 |
Tecnologie a supporto del rilevamento della prossimità: riflessioni per il cittadino, i professionisti e gli stakeholder in era COVID-19. Versione del 31 maggio 2020 D Giansanti, G D’Avenio, M Rossi, A Spurio, L Bertinato, M Grigioni Roma: Istituto Superiore di Sanità, 2020 | 23 | 2020 |
Flow on the symmetry plane of a total cavo-pulmonary connection G Bolzon, G Pedrizzetti, M Grigioni, L Zovatto, C Daniele, G D'Avenio Journal of biomechanics 35 (5), 595-608, 2002 | 22 | 2002 |
Laser Doppler anemometry study of bidimensional flows downstream of three 19 mm bileaflet valves in the mitral position, under kinematic similarity M Grigioni, C Daniele, G D'avenio, V Barbaro Annals of Biomedical Engineering 28, 194-203, 2000 | 22 | 2000 |
19 mm sized bileaflet valve prostheses’ flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses) V Barbaro, M Grigioni, C Daniele, G D'avenio, G Boccanera The International Journal of Artificial Organs 20 (11), 629-636, 1997 | 21 | 1997 |