Follow
Giuseppe D'Avenio
Giuseppe D'Avenio
Verified email at iss.it
Title
Cited by
Cited by
Year
A novel formulation for blood trauma prediction by a modified power-law mathematical model
M Grigioni, U Morbiducci, G D’Avenio, GD Benedetto, CD Gaudio
Biomechanics and Modeling in Mechanobiology 4, 249-260, 2005
1772005
The power‐law mathematical model for blood damage prediction: analytical developments and physical inconsistencies
M Grigioni, C Daniele, U Morbiducci, G D’Avenio, G Di Benedetto, ...
Artificial organs 28 (5), 467-475, 2004
1722004
A discussion on the threshold limit for hemolysis related to Reynolds shear stress
M Grigioni, C Daniele, G D'avenio, V Barbaro
Journal of biomechanics 32 (10), 1107-1112, 1999
1191999
A mathematical description of blood spiral flow in vessels: application to a numerical study of flow in arterial bending
M Grigioni, C Daniele, U Morbiducci, C Del Gaudio, G D’Avenio, ...
Journal of Biomechanics 38 (7), 1375-1386, 2005
1102005
The influence of the leaflets’ curvature on the flow field in two bileaflet prosthetic heart valves
M Grigioni, C Daniele, G D’Avenio, V Barbaro
Journal of Biomechanics 34 (5), 613-621, 2001
782001
Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow
M Grigioni, C Daniele, U Morbiducci, G D’Avenio, G Di Benedetto, ...
Journal of Biomechanics 35 (12), 1599-1612, 2002
732002
The beneficial vortex and best spatial arrangement in total extracardiac cavopulmonary connection
A Amodeo, M Grigioni, G Oppido, C Daniele, G D'Avenio, G Pedrizzetti, ...
The Journal of thoracic and cardiovascular surgery 124 (3), 471-478, 2002
542002
Three-dimensional numeric simulation of flow through an aortic bileaflet valve in a realistic model of aortic root
M Grigioni, C Daniele, C Del Gaudio, U Morbiducci, A Balducci, ...
ASAIO journal 51 (3), 176-183, 2005
502005
Investigation of the flow field downstream of an artificial heart valve by means of PIV and PTV
A Balducci, M Grigioni, G Querzoli, GP Romano, C Daniele, G D’Avenio, ...
Experiments in fluids 36, 204-213, 2004
452004
Virtual microscopy and digital cytology: state of the art
D Giansanti, M Grigioni, G D'Avenio, S Morelli, G Maccioni, A Bondi, ...
Annali dell'Istituto superiore di sanità 46, 115-122, 2010
442010
Particle image velocimetry analysis of the flow field in the total cavopulmonary connection
M Grigioni, A Amodeo, C Daniele, G D'avenio, R Formigari, RM Di Donato
Artificial organs 24 (12), 946-952, 2000
382000
19 mm sized bileaflet valve prostheses’ flow field investigated by bidimensional laser doppler anemometry (part I: velocity profiles)
V Barbaro, M Grigioni, C Daniele, G D'avenio, G Boccanera
The International Journal of Artificial Organs 20 (11), 622-628, 1997
321997
Prosthetic heart valves’ mechanical loading of red blood cells in patients with hereditary membrane defects
M Grigioni, P Caprari, A Tarzia, G D’Avenio
Journal of biomechanics 38 (8), 1557-1565, 2005
312005
Innovative technologies for the assessment of cardiovascular medical devices: state-of-the-art techniques for artificial heart valve testing
M Grigioni, C Daniele, G D'Avenio, U Morbiducci, C Del Gaudio, M Abbate, ...
Expert review of medical devices 1 (1), 81-93, 2004
292004
Evaluation of the surface-averaged load exerted on a blood element by the Reynolds shear stress field provided by artificial cardiovascular devices
M Grigioni, C Daniele, G D’Avenio, V Barbaro
Journal of biomechanics 35 (12), 1613-1622, 2002
292002
Mechanically assisted total cavopulmonary connection with an axial flow pump: computational and in vivo study
F Gandolfo, G Brancaccio, S Donatiello, S Filippelli, G Perri, E Iannace, ...
Artificial Organs 40 (1), 43-49, 2016
272016
Tecnologie a supporto del rilevamento della prossimità: riflessioni per il cittadino, i professionisti e gli stakeholder in era COVID-19. Versione del 31 maggio 2020
D Giansanti, G D’Avenio, M Rossi, A Spurio, L Bertinato, M Grigioni
Roma: Istituto Superiore di Sanità, 2020
232020
Flow on the symmetry plane of a total cavo-pulmonary connection
G Bolzon, G Pedrizzetti, M Grigioni, L Zovatto, C Daniele, G D'Avenio
Journal of biomechanics 35 (5), 595-608, 2002
222002
Laser Doppler anemometry study of bidimensional flows downstream of three 19 mm bileaflet valves in the mitral position, under kinematic similarity
M Grigioni, C Daniele, G D'avenio, V Barbaro
Annals of Biomedical Engineering 28, 194-203, 2000
222000
19 mm sized bileaflet valve prostheses’ flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses)
V Barbaro, M Grigioni, C Daniele, G D'avenio, G Boccanera
The International Journal of Artificial Organs 20 (11), 629-636, 1997
211997
The system can't perform the operation now. Try again later.
Articles 1–20