Quantifying discretization errors for soft tissue simulation in computer assisted surgery: A preliminary study M Duprez, SPA Bordas, M Bucki, HP Bui, F Chouly, V Lleras, C Lobos, ... Applied Mathematical Modelling 77, 709-723, 2020 | 51 | 2020 |
Biomechanical response of varicose veins to elastic compression: A numerical study CPY Rohan, P Badel, B Lun, D Rastel, S Avril Journal of Biomechanics, 2012 | 51 | 2012 |
Prediction of the biomechanical effects of compression therapy on deep veins using finite element modelling PY Rohan, P Badel, B Lun, D Rastel, S Avril Annals of biomedical engineering 43, 314-324, 2015 | 39 | 2015 |
Atlas-based automatic generation of subject-specific finite element tongue meshes A Bijar, PY Rohan, P Perrier, Y Payan Annals of biomedical engineering 44, 16-34, 2016 | 33 | 2016 |
Finite Element simulation of buckling-induced vein tortuosity and influence of the wall constitutive properties P Badel, CPY Rohan, S Avril Journal of the mechanical behavior of biomedical materials 26, 119-126, 2013 | 29 | 2013 |
Combining freehand ultrasound-based indentation and inverse finite element modeling for the identification of hyperelastic material properties of thigh soft tissues N Fougeron, PY Rohan, D Haering, JL Rose, X Bonnet, H Pillet Journal of biomechanical engineering 142 (9), 091004, 2020 | 21 | 2020 |
Passive wrist stiffness: the influence of handedness S Durand, CPY Rohan, T Hamilton, W Skalli, HI Krebs IEEE Transactions on Biomedical Engineering 66 (3), 656-665, 2018 | 20 | 2018 |
Lower-limb lengths and angles in children older than six years: reliability and reference values by EOS® stereoradiography V Rampal, PY Rohan, A Assi, I Ghanem, O Rosello, AL Simon, ... Orthopaedics & Traumatology: Surgery & Research 104 (3), 389-395, 2018 | 20 | 2018 |
Finite element models of the human tongue: a mixed-element mesh approach PY Rohan, C Lobos, MA Nazari, P Perrier, Y Payan Computer Methods in Biomechanics and Biomedical Engineering: Imaging …, 2017 | 20 | 2017 |
Three-dimensional reconstruction using stereoradiography for evaluating adult spinal deformity: a reproducibility study E Ferrero, R Lafage, S Vira, PY Rohan, J Oren, E Delsole, P Guigui, ... European Spine Journal 26, 2112-2120, 2017 | 19 | 2017 |
Digital twinning of Cellular Capsule Technology: Emerging outcomes from the perspective of porous media mechanics S Urcun, PY Rohan, W Skalli, P Nassoy, SPA Bordas, G Sciumè Plos one 16 (7), e0254512, 2021 | 18 | 2021 |
Development and evaluation of a new methodology for the fast generation of patient-specific Finite Element models of the buttock for sitting-acquired deep tissue injury prevention A Macron, H Pillet, J Doridam, A Verney, PY Rohan Journal of Biomechanics 79, 173-180, 2018 | 18 | 2018 |
Is a simplified Finite Element model of the gluteus region able to capture the mechanical response of the internal soft tissues under compression? A Macron, H Pillet, J Doridam, I Rivals, MJ Sadeghinia, A Verney, ... Clinical Biomechanics 71, 92-100, 2020 | 17 | 2020 |
Finite element modelling of nearly incompressible materials and volumetric locking: a case study PY Rohan, C Lobos, MA Nazari, P Perrier, Y Payan Computer methods in biomechanics and biomedical engineering 17 (sup1), 192-193, 2014 | 16 | 2014 |
Three-dimensional reconstruction of foot in the weightbearing position from biplanar radiographs: evaluation of accuracy and reliability PY Rohan, A Perrier, M Ramanoudjame, J Hausselle, H Lelièvre, ... The Journal of Foot and Ankle Surgery 57 (5), 931-937, 2018 | 15 | 2018 |
Role of ligaments in the knee joint kinematic behavior: Development and validation of a finite element model F Germain, PY Rohan, G Rochcongar, P Rouch, P Thoreux, H Pillet, ... Computational Biomechanics for Medicine: Imaging, Modeling and Computing, 15-26, 2016 | 13 | 2016 |
Patient-Specific Modeling of Leg Compression in the Treatment of Venous Deficiency S Avril, P Badel, L Dubuis, PY Rohan, J Debayle, S Couzan, JF Pouget Patient-Specific Modeling in Tomorrow's Medicine, 217-238, 2012 | 12 | 2012 |
Cortex tissue relaxation and slow to medium load rates dependency can be captured by a two-phase flow poroelastic model S Urcun, PY Rohan, G Sciumè, SPA Bordas Journal of the mechanical behavior of biomedical materials 126, 104952, 2022 | 11 | 2022 |
A mechano-biological model of multi-tissue evolution in bone J Frame, PY Rohan, L Corté, R Allena Continuum Mechanics and Thermodynamics 31, 1-31, 2019 | 11 | 2019 |
Microstructural characterization of annulus fibrosus by ultrasonography: a feasibility study with an in vivo and in vitro approach T Langlais, P Desprairies, R Pietton, PY Rohan, J Dubousset, JR Meakin, ... Biomechanics and Modeling in Mechanobiology 18, 1979-1986, 2019 | 10 | 2019 |