关注
Baiyu Chen, PhD, DABR
Baiyu Chen, PhD, DABR
在 google.com 的电子邮件经过验证
标题
引用次数
引用次数
年份
Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Z Yu, S Leng, SM Jorgensen, Z Li, R Gutjahr, B Chen, AF Halaweish, ...
Physics in Medicine & Biology 61 (4), 1572, 2016
2612016
Lowdose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
CH McCollough, AC Bartley, RE Carter, B Chen, TA Drees, P Edwards, ...
Medical Physics 44 (10), 2017
2482017
Lowdose CT image and projection dataset
TR Moen, B Chen, DR Holmes III, X Duan, Z Yu, L Yu, S Leng, JG Fletcher, ...
Medical physics 48 (2), 902-911, 2021
1912021
Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods
B Chen, O Christianson, JM Wilson, E Samei
Medical physics 41 (7), 071909, 2014
1422014
Radiation dose reduction in abdominal computed tomography during the late hepatic arterial phase using a model-based iterative reconstruction algorithm: how low can we go?
DB Husarik, D Marin, E Samei, S Richard, B Chen, TA Jaffe, MR Bashir, ...
Investigative radiology 47 (8), 468-474, 2012
752012
An anthropomorphic breast model for breast imaging simulation and optimization
B Chen, J Shorey, RS Saunders Jr, S Richard, J Thompson, LW Nolte, ...
Academic Radiology 18 (5), 536-546, 2011
752011
Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)
B Chen, H Barnhart, S Richard, M Robins, J Colsher, E Samei
Medical Physics 40 (11), 111902, 2013
682013
Evaluating iterative reconstruction performance in computed tomography
B Chen, JCR Giraldo, J Solomon, E Samei
Medical physics 41 (12), 121913, 2014
652014
Initial results from a prototype whole-body photon-counting computed tomography system
Z Yu, S Leng, SM Jorgensen, Z Li, R Gutjahr, B Chen, X Duan, ...
SPIE Medical Imaging, 94120W-94120W-7, 2015
632015
Validation study of a new semi-automated software program for CT body composition analysis
N Takahashi, M Sugimoto, SP Psutka, B Chen, MR Moynagh, RE Carter
Abdominal Radiology 42 (9), 2369-2375, 2017
602017
Correlation between a 2D channelized Hotelling observer and human observers in a lowcontrast detection task with multislice reading in CT
L Yu, B Chen, JM Kofler, CP Favazza, S Leng, MA Kupinski, ...
Medical physics 44 (8), 3990-3999, 2017
502017
Construction of realistic phantoms from patient images and a commercial three-dimensional printer
S Leng, B Chen, T Vrieze, J Kuhlmann, L Yu, A Alexander, J Matsumoto, ...
Journal of Medical Imaging 3 (3), 033501, 2016
472016
Quantitative CT: technique dependence of volume estimation on pulmonary nodules
B Chen, H Barnhart, S Richard, J Colsher, M Amurao, E Samei
Physics in Medicine & Biology 57 (5), 1335, 2012
392012
Technical Note: Development and validation of an open data format for CT projection data
B Chen, X Duan, Z Yu, S Leng, L Yu, C McCollough
Medical Physics 42 (12), 6964-6972, 2015
352015
Task-based strategy for optimized contrast enhanced breast imaging: analysis of six imaging techniques for mammography and tomosynthesis
L Ikejimba, N Kiarashi, Y Lin, B Chen, SV Ghate, M Zerhouni, E Samei, ...
SPIE Medical Imaging, 831309-831309-7, 2012
342012
Precision of Iodine Quantification in Hepatic CT: Effects of Iterative Reconstruction With Various Imaging Parameters
B Chen, D Marin, S Richard, D Husarik, R Nelson, E Samei
American Journal of Roentgenology 200 (5), W475-W482, 2013
262013
Lesion insertion in the projection domain: Methods and initial results
B Chen, S Leng, L Yu, Z Yu, C Ma, C McCollough
Medical Physics 42 (12), 7034-7042, 2015
232015
An open library of CT patient projection data
B Chen, S Leng, L Yu, D Holmes, J Fletcher, C McCollough
SPIE Medical Imaging, 97831B-97831B-6, 2016
222016
CT performance as a variable function of resolution, noise, and task property for iterative reconstructions
B Chen, S Richard, O Christianson, X Zhou, E Samei
SPIE Medical Imaging, 83131K-83131K-6, 2012
222012
Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography
C Ma, L Yu, B Chen, C Favazza, S Leng, C McCollough
Journal of Medical Imaging 3 (2), 023504, 2016
182016
系统目前无法执行此操作,请稍后再试。
文章 1–20