Velocity profiles and unsteady pipe friction in transient flow B Brunone, BW Karney, M Mecarelli, M Ferrante Journal of water resources planning and management 126 (4), 236-244, 2000 | 332 | 2000 |
Detecting leaks in pressurised pipes by means of transients B Brunone, M Ferrante Journal of hydraulic research 39 (5), 539-547, 2001 | 297 | 2001 |
Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis M Ferrante, B Brunone Advances in Water resources 26 (1), 95-105, 2003 | 292 | 2003 |
Pipe system diagnosis and leak detection by unsteady-state tests. 2. Wavelet analysis M Ferrante, B Brunone Advances in water resources 26 (1), 107-116, 2003 | 224 | 2003 |
Wavelets for the analysis of transient pressure signals for leak detection M Ferrante, B Brunone, S Meniconi Journal of hydraulic engineering 133 (11), 1274-1282, 2007 | 157 | 2007 |
Water-hammer pressure waves interaction at cross-section changes in series in viscoelastic pipes S Meniconi, B Brunone, M Ferrante Journal of fluids and structures 33, 44-58, 2012 | 141 | 2012 |
Anomaly pre-localization in distribution–transmission mains by pump trip: preliminary field tests in the Milan pipe system S Meniconi, B Brunone, M Ferrante, C Capponi, CA Carrettini, C Chiesa, ... Journal of Hydroinformatics 17 (3), 377-389, 2015 | 138 | 2015 |
Small amplitude sharp pressure waves to diagnose pipe systems S Meniconi, B Brunone, M Ferrante, C Massari Water Resources Management 25, 79-96, 2011 | 116 | 2011 |
Experimental investigation of coupled frequency and time-domain transient test–based techniques for partial blockage detection in pipelines S Meniconi, HF Duan, PJ Lee, B Brunone, MS Ghidaoui, M Ferrante Journal of hydraulic engineering 139 (10), 1033-1040, 2013 | 114 | 2013 |
Leak detection in branched pipe systems coupling wavelet analysis and a Lagrangian model M Ferrante, B Brunone, S Meniconi Journal of Water Supply: Research and Technology—AQUA 58 (2), 95-106, 2009 | 114 | 2009 |
In-line pipe device checking by short-period analysis of transient tests S Meniconi, B Brunone, M Ferrante Journal of Hydraulic Engineering 137 (7), 713-722, 2011 | 93 | 2011 |
Decay of pressure and energy dissipation in laminar transient flow B Brunone, M Ferrante, M Cacciamani J. Fluids Eng. 126 (6), 928-934, 2004 | 93 | 2004 |
Portable pressure wave‐maker for leak detection and pipe system characterization B Brunone, M Ferrante, S Meniconi Journal‐American Water Works Association 100 (4), 108-116, 2008 | 92 | 2008 |
Experimental investigation of the effects of pipe material on the leak head-discharge relationship M Ferrante Journal of Hydraulic Engineering 138 (8), 736-743, 2012 | 89 | 2012 |
Experimental evidence of hysteresis in the head-discharge relationship for a leak in a polyethylene pipe M Ferrante, C Massari, B Brunone, S Meniconi Journal of Hydraulic Engineering 137 (7), 775-780, 2011 | 89 | 2011 |
Leak detection in a branched system by inverse transient analysis with the admittance matrix method C Capponi, M Ferrante, AC Zecchin, J Gong Water Resources Management 31, 4075-4089, 2017 | 82 | 2017 |
Numerical simulations of one‐dimensional infiltration into layered soils with the Richards equation using different estimates of the interlayer conductivity B Brunone, M Ferrante, N Romano, A Santini Vadose Zone Journal 2 (2), 193-200, 2003 | 78 | 2003 |
Leak size, detectability and test conditions in pressurized pipe systems: how leak size and system conditions affect the effectiveness of leak detection techniques M Ferrante, B Brunone, S Meniconi, BW Karney, C Massari Water resources management 28, 4583-4598, 2014 | 73 | 2014 |
Potential of transient tests to diagnose real supply pipe systems: What can be done with a single extemporary test S Meniconi, B Brunone, M Ferrante, C Massari Journal of Water Resources Planning and Management 137 (2), 238-241, 2011 | 71 | 2011 |
Transient tests for locating and sizing illegal branches in pipe systems S Meniconi, B Brunone, M Ferrante, C Massari Journal of Hydroinformatics 13 (3), 334-345, 2011 | 70 | 2011 |