Achieving annual and monthly net-zero energy of existing building in hot climate A AlAjmi, H Abou-Ziyan, A Ghoneim Applied energy 165, 511-521, 2016 | 127 | 2016 |
Thermal performance of flat plate solar collector using various arrangements of compound honeycomb AH Abdullah, HZ Abou-Ziyan, AA Ghoneim Energy conversion and management 44 (19), 3093-3112, 2003 | 103 | 2003 |
Performance of stationary and vibrated thermosyphon working with water and R134a HZ Abou-Ziyan, A Helali, M Fatouh, MMA El-Nasr Applied thermal engineering 21 (8), 813-830, 2001 | 89 | 2001 |
Solar-assisted R22 and R134a heat pump systems for low-temperature applications HZ Abou-Ziyan, MF Ahmed, MN Metwally, HM Abd El-Hameed Applied Thermal Engineering 17 (5), 455-469, 1997 | 85 | 1997 |
Performance of advanced corrugated-duct solar air collector compared with five conventional designs MN Metwally, HZ Abou-Ziyan, AM El-Leathy Renewable Energy 10 (4), 519-537, 1997 | 76 | 1997 |
Enhancement of forced convection in wide cylindrical annular channel using rotating inner pipe with interrupted helical fins HZ Abou-Ziyan, AHB Helali, MYE Selim International Journal of Heat and Mass Transfer 95, 996-1007, 2016 | 47 | 2016 |
Energy analysis of under-floor air distribution (UFAD) system: An office building case study AF Alajmi, HZ Abou-Ziyan, W El-Amer Energy Conversion and Management 73, 78-85, 2013 | 47 | 2013 |
Convective heat transfer from different brick arrangements in tunnel kilns HZ Abou-Ziyan Applied Thermal Engineering 24 (2-3), 171-191, 2004 | 47 | 2004 |
Experimental investigation of tracking paraboloid and box solar cookers under Egyptian environment HZ Abou-Ziyan Applied Thermal Engineering 18 (12), 1375-1394, 1998 | 42 | 1998 |
Forced convection and subcooled flow boiling heat transfer in asymmetrically heated ducts of T-section HZ Abou-Ziyan Energy conversion and management 45 (7-8), 1043-1065, 2004 | 38 | 2004 |
Heat transfer characteristics of some oils used for engine cooling HZ Abou-Ziyan Energy Conversion and Management 45 (15-16), 2553-2569, 2004 | 35 | 2004 |
Effect of load-sharing operation strategy on the aggregate performance of existed multiple-chiller systems HZ Abou-Ziyan, AF Alajmi Applied energy 135, 329-338, 2014 | 33 | 2014 |
Energy and exergy analysis of a household refrigerator using a ternary hydrocarbon mixture in tropical environment–Effects of refrigerant charge and capillary length M Fatouh, H Abou-Ziyan Applied Thermal Engineering 145, 14-26, 2018 | 28 | 2018 |
Characteristics enhancement of one-section and two-stepwise microchannels for cooling high-concentration multi-junction photovoltaic cells H Abou-Ziyan, M Ibrahim, H Abdel-Hameed Energy conversion and management 206, 112488, 2020 | 24 | 2020 |
Performance characteristics of thin-multilayer activated alumina bed H Abou-Ziyan, D Abd El-Raheim, O Mahmoud, M Fatouh Applied energy 190, 29-42, 2017 | 23 | 2017 |
Effect of gap thickness on a rectangular-cell compound-honeycomb solar collector HZ Abou-Ziyan, RF Richards Solar energy 60 (5), 271-280, 1997 | 18 | 1997 |
Effect of fluid channels on flow uniformity in complex geometry similar to lattice brick setting in tunnel kilns JH Almutairi, MA Alrahmani, IF Almesri, HZ Abou-Ziyan International Journal of Mechanical Sciences 134, 28-40, 2017 | 17 | 2017 |
Differential fluid enthalpy method for predicting heat transfer coefficients in packed beds BS Baclic, PJ Heggs, HZZ Abou Ziyan International Heat Transfer Conference Digital Library, 1986 | 17 | 1986 |
Performance modeling and analysis of high-concentration multi-junction photovoltaics using advanced hybrid cooling systems H Abou-Ziyan, M Ibrahim, H Abdel-Hameed Applied energy 269, 115060, 2020 | 16 | 2020 |
Convective heat transfer coefficients of multifaceted longitudinal and transversal bricks of lattice setting in tunnel kilns HZ Abou-Ziyan, IF Almesri, MA Alrahmani, JH Almutairi Journal of Thermal Science and Engineering Applications 10 (5), 051014, 2018 | 14 | 2018 |