Interlayer Registry to Determine the Sliding Potential of Layered Metal Dichalcogenides: The Case of 2H-MoS2 A Blumberg, U Keshet, I Zaltsman, O Hod The Journal of Physical Chemistry Letters 3 (15), 1936-1940, 2012 | 51 | 2012 |
Comparison of electrospray LC–MS, LC–MS with Cold EI and GC–MS with Cold EI for sample identification S Tsizin, R Bokka, U Keshet, T Alon, AB Fialkov, N Tal, A Amirav International Journal of Mass Spectrometry 422, 119-125, 2017 | 28 | 2017 |
Soft Cold EI–approaching molecular ion only with electron ionization A Amirav, U Keshet, A Danon Rapid Communications in Mass Spectrometry 29 (21), 1954-1960, 2015 | 28 | 2015 |
Open Probe fast GC–MS—combining ambient sampling ultra‐fast separation and in‐vacuum ionization for real‐time analysis U Keshet, T Alon, AB Fialkov, A Amirav Journal of Mass Spectrometry 52 (7), 417-426, 2017 | 17 | 2017 |
A new pulsed flow modulation GC× GC–MS with Cold EI system and its application for jet fuel analysis U Keshet, AB Fialkov, T Alon, A Amirav Chromatographia 79, 741-754, 2016 | 16 | 2016 |
Open Probe fast GC–MS—Real time analysis with separation A Amirav, U Keshet, T Alon, AB Fialkov International Journal of Mass Spectrometry 371, 47-53, 2014 | 15 | 2014 |
Pesticide analysis by pulsed flow modulation GCxGC-MS with Cold EI—an alternative to GC-MS-MS U Keshet, P Goldshlag, A Amirav Analytical and bioanalytical chemistry 410, 5507-5519, 2018 | 14 | 2018 |
Acyl-CoA identification in mouse liver samples using the in silico CoA-Blast tandem mass spectral library U Keshet, T Kind, X Lu, S Devi, O Fiehn Analytical Chemistry 94 (6), 2732-2739, 2022 | 7 | 2022 |
Doubly Charged Molecular Ions in GC–MS with Cold EI KJ Margolin Eren, AB Fialkov, U Keshet, S Tsizin, A Amirav Journal of the American Society for Mass Spectrometry 31 (2), 347-354, 2019 | 7 | 2019 |
Linearity sensitivity and response uniformity comparison of the Aviv Analytical 5975-SMB GC-MS with Cold EI and the Agilent 5977A GC-MS with standard EI A Amirav, U Keshet, B Belgorodsky Advanced GC-MS Blog Journal, May 8, 2014 | 5 | 2014 |
By how much is the molecular ion enhanced in Cold EI A Amirav, U Keshet, T Alon, AB Fialkov Advanced GC-MS Blog Journal, 2012 | 5 | 2012 |
LibGen: Generating High Quality Spectral Libraries of Natural Products for EAD-, UVPD-, and HCD-High Resolution Mass Spectrometers F Kong, U Keshet, T Shen, E Rodriguez, O Fiehn Analytical Chemistry 95 (46), 16810-16818, 2023 | 1 | 2023 |
Open Probe fast GCâ MS â combining ambient sampling ultraâ fast separation and inâ vacuum ionization for realâ time analysis U Keshet, T Alon, AB Fialkov, A Amirav Journal of mass spectrometry, 2017 | | 2017 |