Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins L Anderson, CL Hunter Molecular & Cellular Proteomics 5 (4), 573-588, 2006 | 1509 | 2006 |
The Paragon Algorithm, a next generation search engine that uses sequence temperature values and feature probabilities to identify peptides from tandem mass spectra IV Shilov, SL Seymour, AA Patel, A Loboda, WH Tang, SP Keating, ... Molecular & Cellular Proteomics 6 (9), 1638-1655, 2007 | 1391 | 2007 |
Multi-laboratory assessment of reproducibility, qualitative and quantitative performance of SWATH-mass spectrometry BC Collins, CL Hunter, Y Liu, B Schilling, G Rosenberger, SL Bader, ... Nature communications 8 (1), 291, 2017 | 508 | 2017 |
Design and chemical synthesis of a homogeneous polymer-modified erythropoiesis protein GG Kochendoerfer, SY Chen, F Mao, S Cressman, S Traviglia, H Shao, ... Science 299 (5608), 884-887, 2003 | 445 | 2003 |
Statistical control of peptide and protein error rates in large-scale targeted data-independent acquisition analyses G Rosenberger, I Bludau, U Schmitt, M Heusel, CL Hunter, Y Liu, ... Nature methods 14 (9), 921-927, 2017 | 212 | 2017 |
Unique scanning capabilities of a new hybrid linear ion trap mass spectrometer (Q TRAP) used for high sensitivity proteomics applications JCY Le Blanc, JW Hager, AMP Ilisiu, C Hunter, F Zhong, I Chu Proteomics 3 (6), 859-869, 2003 | 183 | 2003 |
Structural and functional definition of the human chitinase chitin-binding domain LW Tjoelker, L Gosting, S Frey, CL Hunter, H Le Trong, B Steiner, ... Journal of Biological Chemistry 275 (1), 514-520, 2000 | 154 | 2000 |
Dissociation of Heme from Myoglobin and Cytochrome b5: Comparison of Behavior in Solution and the Gas Phase, CL Hunter, AG Mauk, DJ Douglas Biochemistry 36 (5), 1018-1025, 1997 | 124 | 1997 |
Polymer-modified synthetic proteins GG Kochendoerfer, P Botti, JA Bradburne, S Chen, S Cressman, ... US Patent 7,118,737, 2006 | 119 | 2006 |
Role of the Heme Propionates in the Interaction of Heme with Apomyoglobin and Apocytochrome b5 CL Hunter, E Lloyd, LD Eltis, SP Rafferty, H Lee, M Smith, AG Mauk Biochemistry 36 (5), 1010-1017, 1997 | 112 | 1997 |
Multiplexed, scheduled, high-resolution parallel reaction monitoring on a full scan QqTOF instrument with integrated data-dependent and targeted mass spectrometric workflows B Schilling, B MacLean, JM Held, AK Sahu, MJ Rardin, DJ Sorensen, ... Analytical chemistry 87 (20), 10222-10229, 2015 | 105 | 2015 |
Relative and absolute quantitative expression profiling of cytochromes P450 using isotope‐coded affinity tags RE Jenkins, NR Kitteringham, CL Hunter, S Webb, TJ Hunt, R Elsby, ... Proteomics 6 (6), 1934-1947, 2006 | 101 | 2006 |
Sequential Window Acquisition of all Theoretical Mass Spectra (SWATH) Analysis for Characterization and Quantification of Histone Post-translational Modifications*[S] S Sidoli, S Lin, L Xiong, NV Bhanu, KR Karch, E Johansen, C Hunter, ... Molecular & Cellular Proteomics 14 (9), 2420-2428, 2015 | 93 | 2015 |
Total chemical synthesis of a functional interacting protein pair: the protooncogene H-Ras and the Ras-binding domain of its effector c-Raf1 CFW Becker, CL Hunter, R Seidel, SBH Kent, RS Goody, M Engelhard Proceedings of the National Academy of Sciences 100 (9), 5075-5080, 2003 | 85 | 2003 |
Highly reproducible automated proteomics sample preparation workflow for quantitative mass spectrometry Q Fu, MP Kowalski, M Mastali, SJ Parker, K Sobhani, I Van Den Broek, ... Journal of proteome research 17 (1), 420-428, 2018 | 83 | 2018 |
Generation of High-Quality SWATH® Acquisition Data for Label-free Quantitative Proteomics Studies Using TripleTOF® Mass Spectrometers B Schilling, BW Gibson, CL Hunter Proteomics: Methods and Protocols, 223-233, 2017 | 77 | 2017 |
Coupled global and targeted proteomics of human embryonic stem cells during induced differentiation AK Yocum, TE Gratsch, N Leff, JR Strahler, CL Hunter, AK Walker, ... Molecular & Cellular Proteomics 7 (4), 750-767, 2008 | 71 | 2008 |
A comparison of MS/MS‐based, stable‐isotope‐labeled, quantitation performance on ESI‐quadrupole TOF and MALDI‐TOF/TOF mass spectrometers MA Kuzyk, LB Ohlund, MH Elliott, D Smith, H Qian, A Delaney, CL Hunter, ... Proteomics 9 (12), 3328-3340, 2009 | 70 | 2009 |
Efficient coupled oxidation of heme by an active site variant of horse heart myoglobin DP Hildebrand, H Tang, Y Luo, CL Hunter, M Smith, GD Brayer, AG Mauk Journal of the American Chemical Society 118 (51), 12909-12915, 1996 | 63 | 1996 |
Recommendations for mass spectrometry data quality metrics for open access data (corollary to the Amsterdam Principles) CR Kinsinger, J Apffel, M Baker, X Bian, CH Borchers, R Bradshaw, ... Journal of proteome research 11 (2), 1412-1419, 2012 | 59 | 2012 |