Beamline characterization of a dielectric-filled reentrant cavity resonator as beam current monitor for a medical cyclotron facility S Srinivasan, PA Duperrex, JM Schippers Physica Medica 78 (October 2020), 101-108, 2020 | 13 | 2020 |
Dielectric-filled reentrant cavity resonator as a low-intensity proton beam diagnostic S Srinivasan, PA Duperrex Instruments 2 (4), 24, 2018 | 8 | 2018 |
Predicting Weld Bead Width and Depth of Penetration from Infrared Thermal Image of Weld Pool Using Artificial Neural Networks S Chokkalingham, M Vasudevan, S Sudarsan, N Chandrasekhar Insight-Non-Destructive Testing and Condition Monitoring 54 (5), 272-277, 2012 | 6 | 2012 |
Reentrant cavity resonator for low intensities proton beam measurements S Srinivasan, PA Duperrex Proc IPAC2018, Vancouver, BC, Canada, 2341-4, 2018 | 4 | 2018 |
Lab-Industry Collaboration: Industrialisation of A Novel Non-Interceptive Turn-Key Diagnostic System for Medical Applications S Srinivasan, H Bayle, ET Touzain | 2 | 2022 |
Quadrated dielectric-filled reentrant cavity resonator as a proton beam position siagnostic S Srinivasan, PA Duperrex, JM Schippers Proc. 10th Int. Particle Accelerator Conference, 2676-2679, 2019 | 2 | 2019 |
Numerical Comparative Study of BPM Designs for the HESR at FAIR AJ Halama, C Böhme, V Kamerdzhiev, F Klehr, S Srinivasan International Beam Instrumentation Conference, 2016 | 2 | 2016 |
Non-Interceptive Beam Current and Position Monitors for a Cyclotron Based Proton Therapy Facility S Srinivasan | 1 | 2021 |
REENTRANT CAVITY RESONATOR AS A BEAM CURRENT MONITOR (BCM) FOR A MEDICAL CYCLOTRON FACILITY* S Srinivasan, PA Duperrex, JM Schippers 9th International Beam Instrumentation Conference, 2020 | 1 | 2020 |
Development of a fourfold dielectric-filled reentrant cavity as a beam position monitor (BPM) in a proton therapy facility S Srinivasan, S Brandenburg, JM Schippers, PA Duperrex Journal of Instrumentation 17 (09), P09013, 2022 | | 2022 |
FLASH in the Clinic Track (Oral Presentations) TOWARDS A REAL-TIME TURN-KEY NON-INTERCEPTIVE, NON-SATURATING, BEAM-SIZE-INDEPENDENT FLASH DIAGNOSTICS SYSTEM AT PSI S Srinivasan, PA Duperrex, D Meer, J Schippers, B Baricevic, D Bisiach, ... Physica Medica: European Journal of Medical Physics 94, S53, 2022 | | 2022 |
Measuring beam intensity in FLASH experiments with a non-intercepting and non-saturating monitor S Srinivasan, V Maradia, S Psoroulas, JM Schippers, PA Duperrex 59th Annual Particle Therapy Co-Operative Group Conference (PTCOG 2021), 2021 | | 2021 |
Design of a Four-quadrant Dielectric-filled Reentrant Cavity Resonator as a Proton Beam Position Monitor (BPM) Using HFSS Simulation S Srinivasan, PA Duperrex, JM Schippers, S Brandenburg Non-Interceptive Beam Current and Position Monitors for a Cyclotron Based …, 2021 | | 2021 |
EXPERIMENTS WITH A QUADRATED DIELECTRIC-FILLED REENTRANT CAVITY RESONATOR AS A BEAM POSITION MONITOR (BPM) FOR A MEDICAL CYCLOTRON FACILITY S Srinivasan, PA Duperrex, JM Schippers 9th International Beam Instrumentation Conference, 2020 | | 2020 |
Design and construction of the HESR BPM prototype wire test bench at COSY, Forschungzentrum Juelich S Srinivasan, V Kamerdzhiev, C Boehme Verhandlungen der Deutschen Physikalischen Gesellschaft, 2016 | | 2016 |
Characterization of BPM pickup designs for the HESR rate at FAIR using simulations and numerical calculations A Halama, V Kamerdzhiev, C Boehme, S Srinivasan Verhandlungen der Deutschen Physikalischen Gesellschaft, 2016 | | 2016 |
Design and Construction of a stretched wire test bench to characterize Beam Position Monitor for the High Energy Storage Ring S Srinivasan Kernphysikalische Großgeräte, 2016 | | 2016 |
Beam Diagnostics for the High Energy Storage Ring at FAIR C Böhme, A Halama, V Kamerdzhiev, F Klehr, D Prasuhn, K Reimers, ... | | 2015 |