Follow
Jiyeon Park
Jiyeon Park
University of Florida
Verified email at floridaproton.org - Homepage
Title
Cited by
Cited by
Year
Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in …
JY Park, S Kim, HJ Park, JW Lee, YS Kim, TS Suh
Radiation Oncology 9 (5), 2014
252014
Development of a novel quality assurance system based on rolled‐up and rolled‐out radiochromic films in volumetric modulated arc therapy
JY Park, JW Lee, KS Choi, JS Lee, YH Kim, S Hong, TS Suh
Medical physics 38 (12), 6688-6696, 2011
192011
Inverse verification of the dose distribution for intensity modulated radiation therapy patient-specific quality assurance using dynamic MLC log files
JW Lee, JH Park, JB Chung, JY Park, BY Choe, TS Suh, DH Lee, S Hong, ...
J Korean Phys Soc 55, 1649-56, 2009
162009
Radiobiological model-based bio-anatomical quality assurance in intensity-modulated radiation therapy for prostate cancer
JY Park, JW Lee, JB Chung, KS Choi, YL Kim, BM Park, Y Kim, J Kim, ...
Journal of radiation research 53 (6), 978-988, 2012
132012
Feasibility of photon beam profile deconvolution using a neural network
H Liu, F Li, J Park, S Lebron, J Wu, B Lu, JG Li, C Liu, G Yan
Medical physics, 2018
102018
Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
C Liu, MW Ho, J Park, WC Hsi, X Liang, Z Li, Y Song, H Feng, Y Zhang
Technology in Cancer Research & Treatment 20, 15330338211033076, 2021
92021
Angular under‐sampling effect on VMAT dose calculation: An analysis and a solution strategy
JY Park, F Li, J Li, D Kahler, JC Park, G Yan, C Liu, B Lu
Medical physics 44 (6), 2096-2114, 2017
62017
Commissioning and validation of TOPAS beam model for IBA Proteus-ONE at UFHPTI
C Liu, Y Zhang, Z Li, X Liang, J Park, Y Song, H Feng
Radiation Physics and Chemistry 180, 109256, 2021
52021
Dosimetric accuracy of AAA and acuros XB dose calculations within an air cavity for small fields of a 6-MV flattening filter-free beam
SW Kang, TS Suh, JB Chung, KY Eom, IA Kim, JS Kim, JW Lee, JY Park
Journal of the Korean Physical Society 67 (12), 2138-2145, 2015
52015
Dosimetric effects of magnetic resonance imaging-assisted radiotherapy planning: dose optimization for target volumes at high risk and analytic radiobiological dose evaluation
JY Park, TS Suh, JW Lee, KJ Ahn, HJ Park, BY Choe, S Hong
Journal of Korean medical science 30 (10), 1522-1530, 2015
52015
Effective Organs-at-Risk Dose Sparing in Volumetric Modulated Arc Therapy Using a Half-Beam Technique in Whole Pelvic Irradiation
H Jang, J Park, M Artz, Y Zhang, JC Ricci, S Huh, PB Johnson, MH Kim, ...
Frontiers in Oncology 11, 2021
42021
A sliding-window approach for improved VMAT dose calculation accuracy
HN Alahmad, JY Park, NJ Potter, B Lu, G Yan, C Liu, JG Li
Medical Dosimetry 45 (3), 197-201, 2020
42020
Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer
JY Choi, YJ Won, JY Park, JW Kim, BK Moon, HG Yoon, SH Moon, ...
Progress in Medical Physics 23 (4), 269-278, 2012
42012
Impact of gamma analysis parameters on dose evaluation using Gafchromic EBT2 films
SR Lee, JY Park, TS Suh, HJ Park, JW Lee, WG Jung
Journal of the Korean Physical Society 61 (8), 1319-1324, 2012
42012
Development of volumetric independent dose calculation system for verification of the treatment plan in image-guided adaptive brachytherapy
SW Kang, JB Chung, KH Kim, JY Park, HJ Park, W Cho, S Olberg, TS Suh, ...
Frontiers in Oncology 10, 609, 2020
32020
Tumor phase recognition using cone‐beam computed tomography projections and external surrogate information
P Tsai, G Yan, C Liu, YC Hung, DL Kahler, JY Park, N Potter, JG Li, B Lu
Medical Physics 47 (10), 5077-5089, 2020
22020
Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources
SY Kim, HM Baek, JH Lee, DH Kim, JY Jung, DW Lee, JW Min, JY Park, ...
Journal of Radioanalytical and Nuclear Chemistry 302 (1), 533-541, 2014
22014
Dose distribution according to the tissue composition using wedge filter by radiochromic film
YL Kim, JW Lee, BM Park, JY Jung, JY Park, TS Suh
Journal of the Korean Society of Radiological Technology 35 (2), 157-164, 2012
22012
Development of the Preliminary Quality Assurance Software for GafChromic EBT2 Film Dosimetry
J Park, J Lee, K Choi, W Jung, T Suh
Journal of Applied Clinical Medical Physics 11 (4), 299, 2010
22010
Development of Preliminary Quality Assurance Software for GafChromic (R) EBT2 Film Dosimetry
JY Park, JW Lee, KS Choi, S Hong, BM Park, YK Bae, WG Jung, TS Suh
Korean Journal of Medical Physics 21 (1), 113-119, 2010
22010
The system can't perform the operation now. Try again later.
Articles 1–20